Topic · 126 of 362 questions freeTopic 1: Deployment
Question 121Choose 1
A network administrator is configuring Snort inspection policies and is seeing failed
deployment messages in Cisco FMC. What information should the administrator generate
for Cisco TAC to help troubleshoot?
Correct answer:
B. A "troubleshoot" file for the device in question.
Explanation
When a policy deployment fails on a Cisco Firepower Threat Defense (FTD) device managed by the FMC—especially an issue related to Snort inspection policies—the most critical piece of information for Cisco TAC is the troubleshoot file generated for that specific managed device.
This file contains detailed logs of the policy deployment process, Snort policy compilation errors, rule validation failures, and the device's system state. It captures exactly what happened during the failed deployment, allowing TAC to pinpoint the exact rule or configuration issue causing the failure.
Why the Other Options Are Incorrect
A. A "show tech" file for the device in question:
A `show tech` file provides general system health and configuration data. It does not contain the specific Snort compilation logs and policy deployment traces needed to troubleshoot a failed policy deployment.
C. A "troubleshoot" file for the Cisco FMC:
This file captures the management platform's state. Since the failure is happening on the managed device (Snort inspection policies failing to deploy), the device's troubleshoot file is required.
D. A "show tech" for the Cisco FMC:
Similar to option C, this focuses on the FMC server and does not contain the detailed device-side deployment error logs.
Reference
Cisco Documentation: "Cisco Firepower Management Center Configuration Guide" – Section on Troubleshooting Policy Deployments, which explains how to generate troubleshoot files for managed devices to diagnose deployment failures.
Question 122Choose 1
Which Cisco FMC report gives the analyst information about the ports and protocols that
are related to the configured sensitive network for analysis?
Correct answer:
B. Host Report
Explanation
In Cisco Firepower Management Center (FMC), the Host Report is designed to provide detailed information about a specific host on the network. This report includes sections that list the protocols and ports observed for that host, which directly helps an analyst understand the network activity associated with a sensitive host.
According to Cisco documentation, the Host Report template provides information about a specific host on the network, and it includes sections that detail the protocols detected in the traffic associated with that host. This is the most appropriate report for analyzing ports and protocols related to a configured sensitive network host.
Why the Other Options Are Incorrect
A. Malware Report:
This report focuses on malware events and file dispositions, not on the ports and protocols associated with a specific sensitive host.
C. Firepower Report:
This is a general report template that provides overall information about the organization's network, but it does not specifically focus on the ports and protocols of a single sensitive host.
D. Network Report:
While a Network Risk Report exists, it is a high-level summary of risks on the network and does not provide the detailed port and protocol breakdown for a specific sensitive host that the Host Report offers.
Reference
Cisco Documentation: "FireSIGHT System User Guide" – Section on Predefined Report Templates, which states the Host Report provides information about a specific host on the network, including protocols detected in the traffic associated with that host.
Question 123Choose 1
An analyst is investigating a potentially compromised endpoint within the network and pulls
a host report for the endpoint in question to collect metrics and documentation. What
information should be taken from this report for the investigation?
Correct answer:
C. intrusion events, host connections, and user sessions
Explanation:
When an analyst is investigating a potentially compromised endpoint and pulls a Host Report, the goal is to gather comprehensive metrics about that specific host's activity and security posture. The Cisco FMC Host Report includes several sections that provide critical investigative data:
Intrusion Events: This shows any IPS or Snort events associated with the host, indicating if it has been targeted by or is originating attacks.
Host Connections: This details the network connections initiated by or involving the host, helping identify command-and-control (C2) traffic or lateral movement.
User Sessions: This lists the users who have logged into or used the host, which is crucial for tracking account compromise and identifying the human element behind the activity.
These elements provide a complete picture of the endpoint's behavior, making it the correct choice for a compromise investigation.
Why the Other Options Are Incorrect
A. client applications by user, web applications, and user connections: While these are useful for general traffic analysis, they are not the primary sections of a Host Report that indicate compromise. This option is a distractor that mixes up general application data.
B. number of attacked machines, sources of the attack, and traffic patterns: This information is more aligned with a Network Risk Report or an Attacks Risk Report, which provide a high-level view of attack trends across the network, rather than focusing on a single endpoint.
D. threat detections over time and application protocols transferring malware: This sounds like a combination of features from the Advanced Malware Risk Report and file analysis tools, not the standard sections provided in the Host Report for a single endpoint.
Reference
Cisco Documentation: "Cisco Firepower Management Center Configuration Guide" – Section on Host Report Templates, which lists the sections included in the Host Report (Intrusion Events, Host Connections, User Sessions, etc.).
Question 124Choose 1
An engineer attempts to pull the configuration for a Cisco FTD sensor to review with Cisco
TAC but does not have direct access to the CU for the device. The CLl for the device is
managed by Cisco FMC to which the engineer has access. Which action in Cisco FMC
grants access to the CLl for the device?
Correct answer:
C. Use the show run all command in the Cisco FTD CLI feature within Cisco FMC
Explanation:
When a Cisco Firepower Threat Defense (FTD) device is managed by a Cisco Firepower Management Center (FMC), the engineer may not have direct console or SSH access to the FTD's CLI. However, the FMC provides a built-in CLI tool for each managed FTD device.
To review the full running configuration of the FTD sensor without direct device access, the engineer can navigate to the device in the FMC, open the CLI interface (often found under the device's advanced options or via the "Open CLI" feature), and execute the show run all command. This command outputs the complete, unabbreviated running configuration directly in the FMC web interface, which can then be copied and shared with Cisco TAC.
Why the Other Options Are Incorrect
A. Export the configuration using the Import/Export tool within Cisco FMC: The Import/Export tool is used for exporting FMC configuration objects (like policies and objects) for backup or transfer to another FMC. It does not export the raw CLI configuration of a managed FTD device.
B. Create a backup of the configuration within the Cisco FMC: Creating a backup generates an encrypted archive file (.tar) for disaster recovery. It does not provide a readable configuration file that an engineer can review with TAC.
D. Download the configuration file within the File Download section of Cisco FMC: There is no direct "File Download" section in the FMC to download the running configuration of an FTD sensor. The configuration must be viewed via the CLI tool.
Reference
Cisco Documentation: "Cisco Firepower Management Center Configuration Guide" – Section on FTD CLI Access via FMC, which explains how to use the built-in CLI tool to run commands like show run on managed devices.
Question 125Choose 1
An engineer is monitoring network traffic from their sales and product development
departments, which are on two separate networks What must be configured in order to
maintain data privacy for both departments?
Correct answer:
B. Use 802 1Q mime set Trunk interfaces with VLANs to maintain logical traffic separation
Explanation
To maintain data privacy and logical separation between two separate departments (sales and product development) while using the same physical Cisco FTD appliance, you should use VLANs.
By configuring the inline interfaces as 802.1Q trunks, the FTD can receive and inspect traffic from both departments while keeping them logically separated using VLAN tags. You can then assign these VLANs to different Security Zones and apply separate Access Control Policies and inspection rules for each department. This ensures that the traffic is inspected securely and data privacy is maintained without the cost and complexity of dedicated physical appliances for each department.
Why the Other Options Are Incorrect
A. Use a dedicated IPS inline set for each department to maintain traffic separation:
While this provides physical separation, it is an expensive and inefficient use of hardware. It consumes two dedicated physical interfaces per department. VLAN trunking is the standard and scalable method for logical separation.
C. Use passive IDS ports for both departments:
Passive IDS ports only monitor a copy of the traffic; they do not sit in the traffic path, and they do not provide a mechanism for enforcing policy (like blocking) or active privacy enforcement.
D. Use one pair of inline set in TAP mode for both departments:
TAP mode (inline tap) is used for passive monitoring of traffic on an inline set without dropping packets. It does not provide logical traffic separation (privacy) between different networks, as the traffic is just aggregated and inspected.
Reference
Cisco Documentation: "Cisco Firepower Management Center Configuration Guide" – Section on Inline Sets and VLAN Tagging, which explains how to configure inline interfaces as trunks to inspect multiple VLANs while maintaining separation.
Question 126Choose 1
An administrator is configuring their transparent Cisco FTD device to receive ERSPAN traffic from multiple switches on a passive port, but the Cisco FTD is not processing the traffic. What is the problem?
Correct answer:
D.
The Cisco FTD must be configured with an ERSPAN port not a passive port.
Explanation
In Cisco Firepower Threat Defense (FTD), receiving ERSPAN (Encapsulated Remote Switched Port Analyzer) traffic requires a specific interface configuration. ERSPAN encapsulates mirrored traffic into GRE (Generic Routing Encapsulation) packets.
An FTD interface configured as a standard Passive interface does not have the capability to decapsulate GRE or process ERSPAN traffic; it only expects raw Ethernet frames. To receive and inspect ERSPAN traffic, the interface must be explicitly configured as an ERSPAN passive interface (or ERSPAN port) in the FMC. The FTD uses this dedicated mode to terminate the GRE tunnel, decapsulate the traffic, and pass the inner packets to the Snort engine for inspection.
Why the Other Options Are Incorrect
A. The switches do not have Layer 3 connectivity to the FTD device for GRE traffic transmission:
While Layer 3 connectivity is necessary for ERSPAN, the question states the traffic is being sent but not processed. The immediate issue is the FTD interface configuration, not the underlying routing.
B. The switches were not set up with a monitor session ID that matches the flow ID defined on the Cisco FTD:
FTD does not require a matching session ID or flow ID to process ERSPAN; it processes the GRE encapsulated packets based on the interface configuration.
C. The Cisco FTD must be in routed mode to process ERSPAN traffic:
ERSPAN is a passive monitoring technology and is supported in transparent mode (and routed mode). The firewall mode is not the limiting factor here; the interface type is.
Reference
Cisco Documentation: "Cisco Firepower Management Center Configuration Guide" – Section on ERSPAN Passive Interfaces, which explains that an interface must be configured specifically as an ERSPAN passive interface to receive and process ERSPAN traffic.
Topic · 8 of 24 questions freeTopic 2: Configuration
Question 127Choose 1
Which Firepower feature allows users to configure bridges in routed mode and enables
devices to perform Layer 2 switching between interfaces?
Correct answer:
D. IRB
Explanation
Integrated Routing and Bridging (IRB) is the Firepower feature that allows you to configure bridge groups within routed mode and perform Layer 2 switching between member interfaces. According to Cisco documentation, bridge groups are supported in both transparent and routed firewall modes. When a Bridge Virtual Interface (BVI) is configured in routed mode, the BVI participates in routing like any other regular interface, while the member interfaces of the bridge group continue to switch traffic at Layer 2 based on destination MAC address lookups. This provides the capability described in the question: configuring bridge groups in routed mode while enabling Layer 2 switching between interfaces.
Why the Other Options Are Incorrect
A. FlexConfig: FlexConfig is a feature used to push CLI commands to FTD for settings that are not natively exposed in FMC. It is not a bridging or switching feature.
B. BDI: Bridge Domain Interface (BDI) is a term used in Cisco IOS XE router configurations. It is not the native FTD feature used to configure bridge groups in routed mode.
C. SGT: Security Group Tag (SGT) is associated with Cisco TrustSec identity-based segmentation. It is unrelated to Layer 2 bridging.
Reference
Cisco Firepower Management Center Configuration Guide: Bridge groups are supported in both transparent and routed firewall modes. When a BVI is named, it participates in routing like any other regular interface.
Question 128Choose 1
An organization is using a Cisco FTD and Cisco ISE to perform identity-based access
controls. A network administrator is analyzing the Cisco FTD events and notices that
unknown user traffic is being allowed through the firewall. How should this be addressed to
block the traffic while allowing legitimate user traffic?
Correct answer:
B. Modify Cisco ISE to send only legitimate usernames to the Cisco FTD.
Explanation
Cisco FTD's identity policy itself does not block traffic; it is responsible for collecting user identity information. Cisco documentation explains that authentication failure does not automatically prevent network access. Identity policies collect user identity information only, and access control rules must be used to prevent users who fail authentication from accessing the network. Therefore, the root cause of unknown-user traffic being allowed lies in the access control policy's matching logic, rather than the identity policy alone.
Since authentication is performed through Cisco ISE, adding a deny rule in the ISE authorization policy for users whose authentication result is "Unknown User" or who fail authentication can help prevent unauthorized network access at the network access layer. However, to block traffic through FTD, the access control policy must also contain an appropriate rule that denies traffic from unknown users. Option A is intended to address access enforcement through ISE, but the FTD access control policy must be configured correctly to ensure the desired result.
Why the Other Options Are Incorrect
B. Modify Cisco ISE to send only legitimate usernames to the Cisco FTD: ISE can provide user-IP mappings based on observed network activity. Selectively withholding mappings for unknown users would leave FTD unable to identify those users, but it would not automatically prevent their traffic from passing. Blocking decisions must be enforced through the appropriate access control mechanism.
C. Add the unknown user in the Access Control Policy in Cisco FTD: FTD access control rules can match the Unknown user condition and deny the associated traffic. This is a direct FTD-side enforcement method and may be appropriate when the requirement is specifically to block unknown users at FTD. The rule must be correctly configured and ordered so that it is evaluated before any broader rule that permits the traffic.
D. Add the unknown user in the Malware & File Policy in Cisco FTD: Malware and file policies are used for file inspection and advanced malware protection. They do not provide the required identity-based network access control.
Reference
Cisco Secure Firewall Management Center Device Configuration Guide: Identity policies collect user identity information only. To prevent users who fail authentication from accessing the network, configure appropriate access control rules. Cisco ISE authorization policies can also enforce network access decisions based on authentication results.
Question 129Choose 1
A company is in the process of deploying intrusion prevention with Cisco FTDs managed
by a Cisco FMC. An engineer must configure policies to detect potential intrusions but not
block the suspicious traffic. Which action accomplishes this task?
Correct answer:
D. Configure IDS mode when creating or editing a policy rule under the Cisco FMC
Intrusion tab in Access Policies section by checking the "Drop when inline" option.
Explanation
In Cisco FMC, the official name of the intrusion policy is IPS, and FMC does not provide a separate IDS mode toggle. To configure the policy for detection without blocking traffic, uncheck the Drop when Inline option in the intrusion policy. Cisco's official documentation explains that checking Drop when Inline allows intrusion rules to affect traffic and generate events, while unchecking it prevents intrusion rules from affecting traffic but still generates events. Therefore, unchecking this option allows the policy to function like an IDS by detecting suspicious activity without blocking traffic through intrusion-rule actions.
Why the Other Options Are Incorrect
A. Configure IDS mode by checking the Drop when Inline option: Checking this option allows intrusion rules to affect traffic, enabling blocking behavior when applicable. This contradicts the requirement to detect suspicious traffic without blocking it.
B. Configure IPS mode by unchecking the Drop when Inline option: Unchecking this option does achieve the required non-blocking behavior. However, Cisco calls the policy an intrusion policy or IPS policy rather than providing a separate IDS mode. The key configuration change is to uncheck Drop when Inline.
C. Configure IPS mode by checking the Drop when Inline option: Checking this option allows intrusion rules to affect traffic, including dropping traffic when applicable. This contradicts the requirement for detection without blocking.
Reference
Cisco Firepower Management Center Configuration Guide: Check the Drop when Inline check box to allow intrusion rules to affect traffic and generate events. Uncheck Drop when Inline to prevent intrusion rules from affecting traffic while still generating events.
Question 130Choose 1
What is the result of specifying of QoS rule that has a rate limit that is greater than the
maximum throughput of an interface?
Correct answer:
B. Matching traffic is not rate limited.
Explanation
According to Cisco's official Firepower Management Center documentation, when configuring a QoS rule, if the specified rate limit is greater than the maximum throughput of the interface, the system does not rate limit matching traffic. The maximum throughput may depend on the hardware configuration and capabilities of the interface.
Why the Other Options Are Incorrect
A. The rate-limiting rule is disabled: The rule is not necessarily disabled. It can remain active and be evaluated, but it does not rate limit matching traffic because the configured limit exceeds the interface's maximum throughput.
C. The system rate-limits all traffic: This is incorrect. In this scenario, the system does not rate limit matching traffic, let alone all traffic.
D. The system repeatedly generates warnings: Cisco's documentation does not specify repeated warnings as the result of this configuration. The documented behavior is that matching traffic is not rate limited.
Reference
Cisco Firepower Management Center Configuration Guide — QoS Rule Components: If you specify a limit greater than the maximum throughput of an interface, the system does not rate limit matching traffic.
Timed mock exam
Experience the real exam before you take it
Our timed 300 710 mock exam mirrors the format, number of questions and time limit of the official exam, so you can build speed and stamina.